ACT-750
Save $237.70 on this order paying by wire
Five sizes of titanium-exchanger pool heat pump, 48,000 to 143,000 BTU, on 230V single phase.
Five sizes of titanium-exchanger pool heat pump, 48,000 to 143,000 BTU, on 230V single phase.
Size the unit to your pool volume and the months you actually want to swim — an undersized heat pump never catches up and an oversized one wastes money. Confirm your panel can carry the breaker: 20A on the ACT-750 up to 50A on the ACT-1500 and ACT-1750, all at 230V single phase. These ship on a pallet by LTL freight between 170 and 290 lb, so you need someone to receive the delivery and a clear route to the equipment pad. Inbound freight is quoted per shipment unless the order clears AWG's $50,000 heat pump threshold.
| ACT-750 | 48,000 BTU · COP 5.6 |
|---|---|
| ACT-1100 | 90,000 BTU · COP 6.0 |
| ACT-1250 | 118,000 BTU · COP 6.1 |
| ACT-1500 | 130,000 BTU · COP 6.0 |
| ACT-1750 | 143,000 BTU · COP 6.0 |
| Voltage / Hz / Phase | 230 / 60 / 1 |
|---|---|
| Minimum Breaker | 20A (ACT-750) · 30A (ACT-1100) · 40A (ACT-1250) · 50A (ACT-1500, ACT-1750) |
| Water Flow Rate | 15–50 GPM (ACT-750) · 20–70 GPM (all other models) |
|---|---|
| Heat Exchanger | Titanium |
| Compressor | Scroll |
|---|---|
| Defrost | Automatic |
| Cabinet (L×W×H) | 28×28×26 in (ACT-750) · 39×30×35 in (all other models) |
|---|---|
| Shipping Weight | 170 / 240 / 240 / 250 / 290 lb by model |
| Low Ambient Cut-out | Low-pressure switch stops the unit around 40°F ambient air |
|---|